F1500UPS 1500VA - 2RU Uninterruptible Power Supply and Voltage Regulator
Uninterruptible power supply - battery backup / power conditioner. 2RU, AVR, RS-232 & USB Interface; BlueBOLT compatible.
The Furman F1500-UPS battery backup is designed exclusively for audio/video professionals and home theater aficionados.
For decades, traditional audio/video components were simple analog devices designed to easily weather power outages of well over two seconds. Later, as computer and microprocessor-based components gained in popularity, their extraordinary sensitivity to even a fraction of a second’s power loss was managed with traditional UPS (uninterruptible power supply) technology.
Unfortunately, these units were solely designed for the I.T. professional. Though they included many technologies and features appropriate to that application, they fell short for premium audio/video components. Though many of these manufacturers later recognized the ever-emerging professional audio/video, broadcast, and home theater market, their lack of experience led merely to a re-tooled chassis. These hastily produced UPS devices lacked the technologies necessary to truly optimize protection, performance, and control for today’s audio-video components.
The Furman F1500-UPS more than fills this void, and offers your system unparalleled battery back-up technology, created from the ground up to meet the exacting demands of the world’s most sensitive audio, video and control systems!
Typical UPS systems feature antiquated surge suppression technologies that can cause as much damage and annoying lock-ups as they attempt to prevent. Only Furman offers battery back-up with our road-proven SMP non-sacrificial, zero ground contamination surge suppression technology, and EVS Extreme Voltage Shutdown. After all, the most robust battery cannot function if the accompanying circuits are damaged. With Furman’s F1500-UPS, you can expect years of trouble-free operation.
Though many control devices are relatively immune to moderate levels of AC line noise, today’s more sensitive devices (such as DLP projectors and line-level signal processors) certainly are not. High-definition technologies have pushed resolution to levels so extreme that virtually any AC noise capable of coupling with your system’s signal will distort, mask, or destroy the performance advantages we all strive so hard to capture and reproduce. Once again, the F1500-UPS is different. While other UPS devices feature AC line filters suitable for an IT closet, only Furman employs our exclusive Linear Filtering Technology (LiFT) to four discrete isolated outlet banks. This advanced noise filtering technology assures that today’s ultra-wide dynamic range is maintained as it must be – pristine. Remember, less AC noise equals greater content, greater resolution, and higher definition.
The F1500-UPS provides True Sine Wave output when in battery backup mode, ensuring the utmost reliability to all connected equipment while running on battery power.
At 1500VA, the F1500-UPS provides substantial backup time for most critical digital A/V components (see runtime chart). If more runtime is needed, 1500VA battery packs (BATT1500E-EXT) may be daisy-chained to double, triple, and further increase runtime as the application demands.
Audio/video systems can vary greatly in their size and components, and as such, flexibility is needed in determining how a battery backup solution should function under different circumstances. Because of this, Furman has provided open source RS-232 control over four independent AC outlet banks, with a wide range of features to interface with an existing control unit. Dual programmable IR control allows the unit to send a shutdown command to remote components in the event of a blackout – no more expensive projector bulbs to replace in the event of a blackout. Optional TCP/IP control (separate interface card, available Q4), offers remote control over any Internet connection via a truly plug-and-play, hosted, web-based graphical user interface, with full remote control and power monitoring functionality.
* As with any battery back up system, the battery pack must be replaced periodically (2.5 to 3 years typically)
Typical Backup Components
Given the nature of battery backup technology, high-current audio and video components such as power amplifiers, powered subwoofers, and high-wattage displays are not recommended for use with the F1500-UPS. Not only will these components drain battery power quite rapidly, but line impedance will also be raised due to the F1500-UPS’s (or any) AVR and AC to DC inverter, which can induce current compression and noticeably diminish performance with high-current A/V equipment. The following components are ideal for use with the F1500-UPS:
Approximate Run Time, 1500VA **
Battery Backup
AC Protection
Shipping Info
The Furman F1500-UPS battery backup is designed exclusively for audio/video professionals and home theater aficionados.
For decades, traditional audio/video components were simple analog devices designed to easily weather power outages of well over two seconds. Later, as computer and microprocessor-based components gained in popularity, their extraordinary sensitivity to even a fraction of a second’s power loss was managed with traditional UPS (uninterruptible power supply) technology.
Unfortunately, these units were solely designed for the I.T. professional. Though they included many technologies and features appropriate to that application, they fell short for premium audio/video components. Though many of these manufacturers later recognized the ever-emerging professional audio/video, broadcast, and home theater market, their lack of experience led merely to a re-tooled chassis. These hastily produced UPS devices lacked the technologies necessary to truly optimize protection, performance, and control for today’s audio-video components.
The Furman F1500-UPS more than fills this void, and offers your system unparalleled battery back-up technology, created from the ground up to meet the exacting demands of the world’s most sensitive audio, video and control systems!
Typical UPS systems feature antiquated surge suppression technologies that can cause as much damage and annoying lock-ups as they attempt to prevent. Only Furman offers battery back-up with our road-proven SMP non-sacrificial, zero ground contamination surge suppression technology, and EVS Extreme Voltage Shutdown. After all, the most robust battery cannot function if the accompanying circuits are damaged. With Furman’s F1500-UPS, you can expect years of trouble-free operation.
Though many control devices are relatively immune to moderate levels of AC line noise, today’s more sensitive devices (such as DLP projectors and line-level signal processors) certainly are not. High-definition technologies have pushed resolution to levels so extreme that virtually any AC noise capable of coupling with your system’s signal will distort, mask, or destroy the performance advantages we all strive so hard to capture and reproduce. Once again, the F1500-UPS is different. While other UPS devices feature AC line filters suitable for an IT closet, only Furman employs our exclusive Linear Filtering Technology (LiFT) to four discrete isolated outlet banks. This advanced noise filtering technology assures that today’s ultra-wide dynamic range is maintained as it must be – pristine. Remember, less AC noise equals greater content, greater resolution, and higher definition.
The F1500-UPS provides True Sine Wave output when in battery backup mode, ensuring the utmost reliability to all connected equipment while running on battery power.
At 1500VA, the F1500-UPS provides substantial backup time for most critical digital A/V components (see runtime chart). If more runtime is needed, 1500VA battery packs (BATT1500E-EXT) may be daisy-chained to double, triple, and further increase runtime as the application demands.
Audio/video systems can vary greatly in their size and components, and as such, flexibility is needed in determining how a battery backup solution should function under different circumstances. Because of this, Furman has provided open source RS-232 control over four independent AC outlet banks, with a wide range of features to interface with an existing control unit. Dual programmable IR control allows the unit to send a shutdown command to remote components in the event of a blackout – no more expensive projector bulbs to replace in the event of a blackout. Optional TCP/IP control (separate interface card, available Q4), offers remote control over any Internet connection via a truly plug-and-play, hosted, web-based graphical user interface, with full remote control and power monitoring functionality.
* As with any battery back up system, the battery pack must be replaced periodically (2.5 to 3 years typically)
Typical Backup Components
Given the nature of battery backup technology, high-current audio and video components such as power amplifiers, powered subwoofers, and high-wattage displays are not recommended for use with the F1500-UPS. Not only will these components drain battery power quite rapidly, but line impedance will also be raised due to the F1500-UPS’s (or any) AVR and AC to DC inverter, which can induce current compression and noticeably diminish performance with high-current A/V equipment. The following components are ideal for use with the F1500-UPS:
- DAWs
- Satellite Receivers
- Cable Boxes
- Digital Video Recorders
- Media Servers
- External Hard Drives
- Digital Mixing Consoles
- Lamp Based Video Displays
- Control Systems
Approximate Run Time, 1500VA **
- Satellite Reciever or Cable Box = 80 Minutes
- Control System + Media Server = 40 Minutes
- Digital Mixing Console (24 channel) = 20 minutes
- DAW Computer + Digital I/O + External Hard Drive + 24” LCD Monitor = 7 minutes
** These run times should be used as a guideline only and are dependant on device and usage.
Specifications:
General- Family: F-Battery
- Line Voltage: 120 (Volts)
- Number of Outlets: 8
- Number of Isolated Banks: 2
- Outlet Descriptions: All 8 outlets surge protected, linearly filtered, and backed up
- Rack-Mountable: Yes
- Rack Ears Included: Yes
- Front Panel Meter(s): LCD Displays status and menu navigation items
- Front Media Light(s): No
- Control: Remote control through RS-232 interface card or via internet with BlueBOLT-CV1 card (sold separately)
- AC Power Cord: Heavy-duty captive power cord
- Dimensions: 17" W (19" w/ rack ears) x 19.2" D x 3.5" H (4" tall with feet installed)
- Weight: 72 lbs.
Battery Backup
- Input Frequency: 47 - 63 Hz
- Regulation Capture Range:
96 - 135V (Sensitive Mode)
93 - 142V (Standard Mode) - Output Frequency: 60 Hz ± 1%
- UPS Output Capacity: 1500VA, 900W @ 0.6pf
- Regulation Output Range:
120V ± 5% (Sensitive Mode)
120V ± 10% (Standard Mode) - UPS Backup Time (Full Load): 12 minutes
- UPS Backup Time (Half Load): 32 minutes
- Transfer Time: < 4ms
AC Protection
- AC Protection Technology: Non-sacrificial SMP (Series Multi-Stage Protection)
- Over-Voltage Shutoff:
150V ± 5V (fast rise)
140 ± 5V (slow rise) - Maximum Current Rating: 12 (Amps)
- Filtration:
Filtration Technology: Linear Filtering Technology (LiFT) - Filtration Rating:
10 dB @ 10kHz
40 dB @ 100 kHz
50 dB @ 500kHz
Shipping Info
- Length: 26 (Inches)
- Width: 22.9 (Inches)
- Height: 10.8 (Inches)
- Weight: 85.4 (Lbs)
- Unit of Measure: Each
- UPC: 654061028185